Choose your Region

Are you sure you want to proceed?

You will be leaving the Cook Medical website that you were viewing and going to a Cook Medical website for another region or country. Not all products are approved in all regulatory jurisdictions. The product information on these websites is intended only for licensed physicians and healthcare professionals.

Endoscopy

Evolution colonic stent as a bridge to surgery


Indication for Procedure

Michael Hünerbein, MD

Michael Hünerbein, MD

The laparoscopic resection of colorectal carcinomas are, more and more, replacing open surgery. This minimally invasive method shows equal oncological results with less perioperative pain, a better cosmetic result and a shortened period of recovery. A contraindication for the laparoscopic procedure is an ileum with dilated intestinal loops, because of an increased risk for perforation. Here, a preoperative stenting with colorectal metal stents offers the opportunity to relieve the ileus and to perform a minimal invasive resection later.

About the Author and Facility

For the past 17 years, Dr. Michael Hünerbein has performed all current endoscopic examinations and interventions, including gastroscopy, colonoscopy and ERCP. The Helios-Hospital Berlin has longstanding experience in stenting, including colorectal stents. The hospital is certified as a reference center for surgical endoscopy by the German Society of Surgery.

Device and Accessories

A standard colonoscope and a fluoroscope are used in this procedure. For the x-ray image, a water-soluble contrast is used. The stenosis is probed using a guide wire with a hydrophilic tip. Over the guide wire, an uncovered Evolution Controlled-Release Colonic stent (available in lengths of 6, 8 or 10 cm) is pushed through the stenosis. The distal end of the stent is deployed and the positioning rectified, as the situation requires. When positioned correctly, the stent can be fully deployed.
Refer to the Evolution® Colonic Controlled-Release Stent – Uncovered product page for the complete Instructions for Use.

Dr. Michael Hünerbein was not a paid consultant of Cook Medical at the time of this publication

Thank You for Your Interest in Cook Medical's Products

The product information on this website is intended only for physicians and healthcare professionals licensed in the European Union (except France), the United Kingdom, Switzerland, Norway, Iceland, Turkey, and Liechtenstein. If you are located in another global region, please click on the regional flag at the very top of the webpage and choose your region from the drop-down options.

If your region is not listed, visit our How to Order section for more information.

Information provided on this site is not intended to be professional medical advice. Product Instructions for Use (IFU) should be consulted before use of any product.

Decline